HOMAGE Introduces UPS For Air Conditioners

Appeared in news papers ads, Homage has introduced 4200 Watts / 5000 VA UPS under the brand name of  ‘Homage Inverter Matrix HMX 5000’ . This UPS is capable of running appliances like air conditioners, refrigerators, washing machines, water pumps,vacuum cleaners etc (upto 4200 watts). Check the power rating of your appliances before running them on UPS.



Homage Matrix Series: 

1- HMX 1000:  660 Watts   / 1000 VA  (Inverter/UPS)
2- HMX 2000:  1320 Watts / 2000 VA  (Inverter/UPS)

3- HMX 5000:  4200 Watts / 5000 VA  (Inverter/UPS)

Homage_Matrix_HMX - Benign-Blog
Homage-Matrix-Details-Benign-Blog

Details:
1- HMX 1000 is designed for running 4 tube lights or 8 energy saving lamps, and 4 fans. 1 battery is required.

2- HMX 2000 is designed for running 8 tube lights or 20 energy saving lamps, and 8 fans. 2 batteries are required.

3- HMX 5000 is designed for running 12 tube lights or 30 energy saving lamps, 12 fans, 1 air conditioner (1 ton), 1 refrigerator (12 cubic feet), 1 washing machine. 4 batteries are required.

(Other appliances can also be used but their power consumption must be within the capacity limit of UPS)



Features and specifications of matrix series:

1- HMX1000 and HMX2000 carry 10 A charger. Whereas, HMX5000 has 20 A charger. These UPS’ have intelligent charger for charging batteries at different charging rates to maintain the efficiency and capacity of batteries.

2- HMX1000 is designed for 660 watts (1000 VA) of load capacity. HMX2000 is designed for 1320 watts (2000 VA) and HMX5000 is designed for 4200 watts (5000 VA) of appliances load. All these power inveters are capable of running at full load without malfunctioning.

3- All these models contain overload protection, battery discharge and over charge protection features. These UPS’ also have LCD display to help users monitor the function.

4- Compatible with wide range of input voltage (90 V to 280 V approx.). Therefore, suitable for use in low voltage areas.

5- Output voltage of backup is rated at 230 V (+10% /-18%) approximately with 50 Hz (+/- 0.1 Hz) frequency.

6- These are modified sine wave UPS and carries 20 ms (narrow range) of switch over time. Therefore, recommended for use with general household appliances.

7- All these Power inverters are designed for use with 12 V batteries. Basically designed for vrla batteries (dry lead acid batteries) but also compatible with flooded lead acid batteries.

Also Read:
Mechanism And Principle Of Air Conditioning – Easy Diagrammatic Explanation
Methods For Circuiting UPS And Inverter With The Wiring Of House (UPS Wiring)




Related Posts

Corrosion of Battery Terminals: Explanation, Cleaning & Prevention Sometimes, terminals or posts of lead acid batteries corrode due to which connection between batteries and appliance cuts off completely or weakens. I...
Well & Tube Well Water Cold in Summer and Warm in Winter – Reason You might have observed that well water or water pulled out from deep underground using water pumps is felt cold in summer while hot in winter season ...
How to Fix Limited or No Connection Problem with TP-Link Routers TP-Link is one of the largest networking products manufacturer for home and office needs. The company is headquartered in China and supplies its produ...
Methods For Circuiting UPS & Inverter With Home & Office Wiring Learn how to circuit UPS or Power Inverter with household appliances like fans, tube lights, energy savers, computers etc. Connect your office equipme...
Functions of Different Power Inverter/UPS Buttons, Switches Power Inverter is a device used to invert batteries direct current into alternating current for providing backup to different appliances when main ele...
How to Improve Touchscreen Sensitivity on Android Smartphones Android smartphones users often complain about poor touch response even if they are using an expensive high end mobile phone powered with latest andro...
What Causes Battery Terminals Corrosion in Car Major Causes: - Leaking electrolyte from cracks or loose joints. - Fumes of acid escaping battery through loose joints or vents. - Bad alternator/g...
Why ATM Eats Cards and How to Avoid it Technology has changed the money and banking system. Previously, where ledger books were used for keeping the records of accounts and transactions are...