Solutions for UPS and Power Inverter Problems

Problems related to uninterruptible power supply and Power Inverter have been discussed here with possible remedies. If you have any UPS or Power Inverter related issue, this post is helpful to fix that. Someone might argue why I have made a single post for two separate products. The answer is simple. If a power inverter carries a built-in charger with reasonably low switch over time from external power source to backup batteries, it acts as a UPS. Manufacturers who sell Power Inverters and UPS’ under two different categories provide built-in batteries for UPS which are packed inside the enclosure. But no batteries are provided with Power Inverters and consumers are allowed to connect them to desired size batteries of their choice. Therefore, Power Inverters circuited with larger batteries can be used to provide backup for a longer duration during power outages or scheduled load shedding. In short, UPS and Power Inverter both can be used as uninterrupted power backup source for home and office appliances, mobile communication equipments, servers and much more.



UPS / Power Inverter is not turning on.

Possible Cause & Remedy:
1- Power switch is defective.  Take it to service center for repair.
2- UPS / Inverter is tripped.  Press Trip reset button on UPS / Inverter to reset it.
3- Battery is not connected.  Connect the battery.
4- Battery terminals are loose.  Check battery terminals.
5- Battery terminals are corroded or rusty.  Clean them.
6- Battery is weak.  If it is old, replace it. Otherwise, charge it.
6- Battery is discharged.  Charge it for several hours before putting it to work.
7- Battery is faulty.  Replace battery.
8- Battery terminals are reversed.  Connect terminals correctly. Refer to user’s manual for details.

 

Battery is not getting charged.

Possible Cause & Remedy:
1- Battery is dead.  Replace battery.
2- Rectifiers are burnt.  Take UPS / Inverter to service centre for repair.
3- Fuses are melted.  Replace them.
4- Battery connection is loose.  Check battery terminals for corrosion. Clean them and clamp them firmly.

 

Backup time is shortened.

Possible Cause & Remedy:
1- Too much power consumption.  Disconnect extra load.
2- Battery has worn out.  Change battery.
3- Battery is not properly charged.  Charge it. If charger appears to be faulty, get UPS / Inverter fixed.
4- Battery has lost electrolyte.  Top up flooded lead acid battery with distilled water regularly. Sealed (dry) battery requires replacement.



 

UPS / Power Inverter works only in inverter mode. 

Possible Cause & Remedy:
1- Input is not connected.  Check power cable.
2- Fuse is melted.  Change it.
3- Input protector is effective.  Reset input protector.
4- Input is too high to be accepted.  Check input voltage.
5- Input is too low to be accepted.  Check input voltage.

 

Alarm buzzer beeps continuously. 

Possible Cause & Remedy:
1- Overload.  Disconnect extra load.
2- Cooling fan is stuck.  Take UPS / Inverter to service center or service it yourself.
3- Battery terminals are wrongly connected.  Refer to user’s manual for details.

 

LCD displays fault code.

Possible Cause & Remedy:
1- Internal problem.  UPS / Inverter circuit needs to be repaired.
2- External problem.  Check battery cables, input and output wires, load etc. Correct any fault generating error. (Read user’s manual to determine fault code and its remedy)

 

Hear noise coming out of UPS / Power Inverter.

Possible Cause & Remedy:
1- Wind noise.  It is normal.
2- Fan is noisy.  Clean fan. If problem persists, replace it or get it done by trained personnel.
3- Humming noise produced by non pure sine wave UPS or Inverter.  It is normal.

Also Read:
Why UPS Restarts Or Shutdown The Computer – Reason & Solution
FAQs About Uninterruptible Power Supply (UPS) And Power Inverters




Related Posts

MicroSD, MicroSDHC Benchmark: Performance Test Of Famous Brands MicroSD and MicroSDHC memory cards manufactured by famous companies like SanDisk, Kingston, Samsung, Transcend, Toshiba and halfway popular TwinMOS ha...
One Major Problem With 32 Bit Windows 32 bit Windows' support only 4 GB of RAM except 32 bit server editions which can read more than 4 GB. In case of Windows Vista, Windows 7 (and also Wi...
Mechanism And Principle Of Air Conditioning Ever wondered how you get cool breeze from air conditioner. What is the mechanism actually involved in producing cold air in burning hot summers? Here...
How to Fix Limited Connection Problem with TP-Link Routers TP-Link is one of the largest networking products manufacturer for home and office needs. The company is headquartered in China and supplies its produ...
USB Extension Cable Problem With Portable Hard Drive – Reason & Solution Several people have reported that their portable hard disk drives are not working. When they connect their hard drives to computer, these are not dete...
How to Use Hard Drive and SSD together Hard disk drive and solid state drive are both digital data storage technologies widely used in notebooks, desktop PCs, servers and different gaming p...
How to Enable or Disable Synaptics TouchPad & ClickPad Gestures Synaptics is popular for producing quality human interface products including TouchPads and ClickPads for notebooks. Newer TouchPads are equipped with...
Norton Security 2015 – 60 Days Free Trial Norton Security 2015 (formerly Norton Internet Security) is a next big step taken by Symantec to bring something new and different to attract users at...
1,025 Comments

Add a Comment

Your email address will not be published. Required fields are marked *